{"version":"0.18.0","built_at":"2026-10-16T10:40:38.130Z","license":"CC BY 4.0 © Mike Reams","canonical":"https://catalog.mikereams.com","value_stream":{"id":"VS-290","name":"Leak-to-Repair","industries":["utilities"],"description":"Carry a gas leak from the odor call, survey finding or excavation strike through make-safe, grading, repair and recheck to the records the pipeline safety regulator expects. Where Outage-to-Restoration (VS-240) restores supply after a fault, this stream handles leaks that are dangerous whether or not supply is lost, and feeds the integrity program that decides which mains to replace.","outcome":"Every leak is made safe, graded, repaired within the time its grade allows, rechecked, and reported; repeat leaks shape the replacement plan.","trigger":"A customer or the public reports a gas odor, a leak survey finds a leak, or an excavator strikes a gas line.","aliases":["Gas Leak Response","Odor Call-to-Repair","Leak Management Lifecycle","Survey-to-Repair"],"stages":[{"id":"VS-290.10","order":1,"name":"Receive the Report","description":"Take the odor call, survey finding or strike report, decide how urgent it is, and dispatch a first responder within the required time.","capability_ids":["BC-1530.50","BC-450.20","BC-1520.40"]},{"id":"VS-290.20","order":2,"name":"Make Safe","description":"Find the gas, protect the public and property, shut off supply where needed and relight customers once it is safe.","capability_ids":["BC-1530.50","BC-1530.50.60"]},{"id":"VS-290.30","order":3,"name":"Grade the Leak","description":"Classify the leak by hazard so it is repaired at once, scheduled within the allowed time, or monitored.","capability_ids":["BC-1530.50.40"]},{"id":"VS-290.40","order":4,"name":"Repair","description":"Locate other buried lines, excavate and repair or replace the leaking main or service, and record what was found.","capability_ids":["BC-680.30","BC-1520.40"]},{"id":"VS-290.50","order":5,"name":"Recheck & Close","description":"Check the repair for residual gas, confirm the area is clear and close the leak record.","capability_ids":["BC-1530.50.40","BC-680.30"]},{"id":"VS-290.60","order":6,"name":"Report & Prioritize","description":"Report leaks and incidents to the safety regulator, investigate strikes, and feed leak history into the integrity program and main replacement plan.","capability_ids":["BC-1580.30","BC-1520.40.30","BC-680.60"]}]}}